Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Phase: | Single |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Models
|
HF2420S60-100
|
HF2430S60-100
|
HF2420U60-100
|
HF2430U60-100
|
AC mode
|
|
|
||
Rated input voltage
|
220/230Vac
|
110/120Vac
|
||
Input voltage range
|
(170Vac~280Vac) ±2%;(90Vac-280Vac)±2%
|
(90Vac-140Vac)±2%
|
||
Frequency
|
50Hz/ 60Hz (Auto detection)
|
50Hz/ 60Hz (Auto detection)
|
||
Frequency Range
|
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
|
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
|
||
Overload/short circuit protection
|
Circuit breaker
|
Circuit breaker
|
||
Efficiency
|
>95%
|
>95%
|
||
Conversion time (bypass and inverter)
|
10ms (typical)
|
10ms (typical)
|
||
AC reverse protection
|
Available
|
Available
|
||
Maximum bypass overload current
|
30A
|
40A
|
||
Inverter mode
|
|
|
||
Output voltage waveform
|
Pure sine wave
|
Pure sine wave
|
||
Rated output power (VA)
|
2000
|
3000
|
2000
|
3000
|
Rated output power (W)
|
2000
|
3000
|
2000
|
3000
|
Power factor
|
1
|
1
|
||
Rated output voltage (Vac)
|
230Vac
|
120Vac
|
||
Output voltage error
|
±5%
|
±5%
|
||
Output frequency range (Hz)
|
50Hz ± 0.3Hz/60Hz ± 0.3Hz
|
50Hz ± 0.3Hz/60Hz ± 0.3Hz
|
||
Efficiency
|
>92%
|
>92%
|
||
Overload protection
|
(102% < load<125%) ±10%: report error and turn off
the output after5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; |
(102% < load <110%) ±10%: report error and turn off the output after5 minutes; (110% < load < 125%) ± 10%: report error and turn
off the output after 10 seconds; Load >125% ±10%: report error and turn offthe output after 5 seconds; |
||
Peak power
|
4000
|
6000
|
3000
|
4500
|
Loaded motor capability
|
1HP
|
2HP
|
1HP
|
2HP
|
Output short circuit protection
|
Circuit breaker
|
Circuit breaker
|
||
Bypass breaker specifications
|
30A
|
40A
|
||
Rated battery input voltage
|
24V (Minimum starting voltage 22V)
|
24V (Minimum starting voltage 22V)
|
||
Battery voltage range
|
(20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery settable on LCD screen)
|
20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen)
|
||
Power saving mode
|
Load ≤25W
|
Load ≤50W
|
||
AC charging
|
|
|
||
Battery type
|
Lead acid or lithium battery
|
Lead acid or lithium battery
|
||
Maximum charge current
|
60A
|
80A
|
40A
|
40A
|
Charge current error
|
± 5Adc
|
± 5Adc
|
||
Charge voltage range
|
18.0Vdc~33Vdc
|
20.0Vdc~33Vdc
|
||
Short circuit protection
|
Circuit breaker and blown fuse
|
Circuit breaker and blown fuse
|
||
Circuit breaker specifications
|
30A
|
40A
|
||
Overcharge protection
|
Alarm and turn off charging after 1 minute
|
Alarm and turn off charging after 1 minute
|
||
PV charging
|
|
|
||
Maximum PV open circuit voltage
|
100Vdc
|
100Vdc
|
||
PV operating voltage range
|
30-100Vdc
|
30-100Vdc
|
||
MPPT voltage range
|
30-95Vdc
|
30-85Vdc
|
||
Battery voltage range
|
18-33Vdc
|
20-33Vdc
|
||
Maximum output power
|
1400W
|
1400W
|
||
PV charging current range (can be set)
|
0-60A
|
0-60A
|
||
Charging short circuit protection
|
Blown fuse
|
Blown fuse
|
||
Wiring protection
|
Reverse polarity protection
|
Reverse polarity protection
|
||
Certified specifications
|
|
|
||
Certification
|
CE(IEC/EN62109-1,-2),ROHS2.0
|
CE(EN62109-1)
|
||
EMC certification level
|
EN61000
|
EN61000, C2
|
||
Operating temperature range
|
-15°C to 55°C
|
-15°C to 55°C
|
||
Storage temperature range
|
-25°C ~ 60°C
|
-25°C ~ 60°C
|
||
Humidity range
|
5% to 95% (Conformal coating protection)
|
5% to 95% (Conformal coating protection)
|
||
Noise
|
≤60dB
|
≤60dB
|
||
Heat dissipation
|
Forced air cooling, variable speed of fan
|
Forced air cooling, variable speed of fan
|
||
Communication interface
|
USB/RS485(Blue tooth/WiFi/GPRS)/Dry node control
|
USB/RS485(WiFi/GPRS)/Dry node control
|
||
Size (L*W*D)
|
378mm*280mm*103mm
|
378mm*280mm*103mm
|
||
Weight (kg)
|
6.2
|
6.8
|
Anhui Wingo Technology Co., Ltd. has set up two sole-funded companies in Heifei one Jointed Venture in Anhui province successively since 2020.Wingo is able to provide customers with annual capacity of 300MW solar cells,400MW solar cells modules and 60,000 sets of solar power systems.
FACTORY DIRECT SOLAR INVERTER WITH TIER 1 BRAND!
FACTORY DIRECT SOLAR PANEL WITH TIER 1 BRAND!
Are you a factory or a trading company?
We are the manufacturer of solar panel and storage battery. Such as inverter, brackets and accessories from our long term
partners. Full certificates with competitive price.
How about the delivery time?
Usually need 10-15 days to prepare. We will update the info for you during our production.
Can i install them by myself?
Each part has installation instructions, convenient installation.For products wire connection, considering security, we suggest you can find an electrician to help you.
What is the payment method?
We accept T/T bank, Western Union payment , Trade assurance.More than 10,000usd, which can pay 30% deposit in advance, pay 70% balance before shipping.
How about the after sales?
Damage in transit will be resolved according to the contract terms.
During the warranty period, if there is a problem with the product, our engineers will first propose a solution according to the specific situation. If the product still has a problem, it will be refunded or replaced for free.